| Model | SUN-3.6K-SG01/03LP1-EU | SUN-5K-SG01/03LP1-EU |
| Battery Input Data | ||
| Battery Type | Lead-acid or Lithium-ion | |
| Battery Voltage Range (V) | 40~60V | |
| Max. Charging Current (A) | 90A | 120A |
| Max. Discharging Current (A) | 90A | 120A |
| Charging Curve | 3 Stages / Equalization | |
| External Temperature Sensor | Optional | |
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |
| PV String Input Data | ||
| Max. DC Input Power (W) | 4680W | 6500W |
| PV Input Voltage (V) | 370V (100V~500V) | |
| MPPT Range (V) | 125~425V | |
| Full Load DC Voltage Range | 240~425V | |
| Start-up Voltage (V) | 150V | |
| PV Input Current (A) | 13A+13A | |
| Max. PV ISC (A) | 17A+17A | |
| No.of MPPT Trackers | 2 | |
| No.of Strings Per MPPT Tracker | 1+1 | |
| AC Output Data | ||
| Rated AC Output and UPS Power (W) | 3600W | 5000W |
| Max. AC Output Power (W) | 3960W | 5500W |
| Peak Power (off grid) | 2 times of rated power, 10 S | |
| AC Output Rated Current (A) | 15.7A | 21.7A |
| Max. AC Current (A) | 18A | 25A |
| Max. Continuous AC Passthrough (A) | 35A | |
| Power Factor | 0.8 leading to 0.8 lagging | |
| Output Frequency and Voltage | 50/60Hz; 220/230 / 240Vac (single phase) | |
| Grid Type | Single Phase | |
| Current Harmonic Distortion | THD<3% (Linear load<1.5%) | |
| Model | SUN-3.6K-SG01/03LP1-EU | SUN-5K-SG01/03LP1-EU |
| Battery Input Data | ||
| Battery Type | Lead-acid or Lithium-ion | |
| Battery Voltage Range (V) | 40~60V | |
| Max. Charging Current (A) | 90A | 120A |
| Max. Discharging Current (A) | 90A | 120A |
| Charging Curve | 3 Stages / Equalization | |
| External Temperature Sensor | Optional | |
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |
| PV String Input Data | ||
| Max. DC Input Power (W) | 4680W | 6500W |
| PV Input Voltage (V) | 370V (100V~500V) | |
| MPPT Range (V) | 125~425V | |
| Full Load DC Voltage Range | 240~425V | |
| Start-up Voltage (V) | 150V | |
| PV Input Current (A) | 13A+13A | |
| Max. PV ISC (A) | 17A+17A | |
| No.of MPPT Trackers | 2 | |
| No.of Strings Per MPPT Tracker | 1+1 | |
| AC Output Data | ||
| Rated AC Output and UPS Power (W) | 3600W | 5000W |
| Max. AC Output Power (W) | 3960W | 5500W |
| Peak Power (off grid) | 2 times of rated power, 10 S | |
| AC Output Rated Current (A) | 15.7A | 21.7A |
| Max. AC Current (A) | 18A | 25A |
| Max. Continuous AC Passthrough (A) | 35A | |
| Power Factor | 0.8 leading to 0.8 lagging | |
| Output Frequency and Voltage | 50/60Hz; 220/230 / 240Vac (single phase) | |
| Grid Type | Single Phase | |
| Current Harmonic Distortion | THD<3% (Linear load<1.5%) | |